The following table contains recommended tensions and maximum
tension to be used in spooling wire line for all E.M. cable.
|
LINE SIZE |
BED WRAP |
2ND LAYER |
3RD LAYER |
MAXIMUM |
| 3/16 | 400 | 800 | 1200 | 1200 |
| 7/32 | 600 | 1200 | 1700 | 1700 |
| 5/16 | 900 | 1800 | 2600 | 2600 |
| 3/8 | 1100 | 2100 | 2800 | 2800 |
Once 1/2 of the cable length has been installed the tension should be reduced by 100 Lbs. per wrap.
|